PRECISION 28000
Signal Conditioning
System






 
|
28608B
Quad Programmable
Filter/Amplifier
The 28608B Octal Programmable Filter/Amplifier Card is ideal
for conditioning low-level voltage inputs in front of high-resolution digital
data acquisition systems. Low-pass, high-pass and band-pass configurations are
available.
The 28608B allows for up to 128 channels of programmable
precision filtering in one 28016B-M3 chassis.
A choice of 4 or 8-pole low-pass filters, 4-pole high-pass and
8-pole band-pass filters are available. Cutoff settings from 1 Hz to 204.6 kHz
are supported. The low-pass filters may operate in either a "flat" mode for
maximally flat pass-band amplitude response with sharp roll-off or in a "pulse"
mode for low phase distortion and optimized transient response.
The "flat" mode provides pass-band characteristics nearly
identical to a Butterworth filter while providing a much sharper roll-off. This
mode is a good choice for applications such as spectral analysis. The "pulse"
mode has time domain response similar to the Bessel filter yet provides superior
amplitude response characteristics. The "pulse" mode is ideal for time domain
applications including transient (shock) measurements and time domain waveform
analysis.
Programmable pre- and post-filter amplifiers provide an
overall gain of 8192. Gain is distributed both before and after the filter to
provide protection from large out-of-band energy or transients that could cause
clipping before the filter, distorting the data. The post-filter gain has
resolution of better than 0.05% to enable system scaling of the outputs to match
the full-scale input of the external recording device. Overload detectors alert
the user to over-voltage conditions. Precise, automated digital calibration of
gain and DC offset are provided.
Other features of the 28608B include a test input for injection
of calibration signals into the channel input and a monitor output that allows
for convenient monitoring of any channel output via a single BNC on the 28000
chassis.
Applications Examples
- Anti-Aliasing Filters with Programmable Amplifiers
- Automatic Test Equipment
- Data Acquisition
- Signal Conditioning
- Production Test Equipment
- Industrial Process Control
- Reconstruction Filters
- Programmable Band-Pass Filters
Back to top
SALIENT FEATURES
|
Number of Channels: |
8 channels per card;
128 channels per
chassis |
|
Inputs: |
Balanced differential with programmable AC/DC coupling |
|
Zero Suppress: |
Programmable DC voltage is inserted at
channel input |
|
Pre-Filter Gain: |
x1 to x512 in x2 steps with input
overload detection |
|
Post-Filter Gain: |
x0.25 to x16 with 0.05% resolution |
|
Filters: |
Choice of 4- or 8-pole low-pass filters
or 8-pole band-pass filters |
|
Cutoff Frequency: |
Pulse Mode Programmable from 1 Hz to
102.3 kHz; Flat Mode programmable from 2 Hz to 204.6 kHz; and wide-band
(500 kHz) |
|
Outputs: |
DC coupled, single-ended with ground sense. Two
additional buffered outputs per channel supported by option front panel
plug-in adapters. |
|
Test Support: |
Test input and monitor output busses |
28608B Channel Diagram
Back to top
Optional Output Adapters
Measurement systems sometimes require multiple outputs per
signal conditioning channel. These outputs may be routed to control systems,
tape backup systems, auxiliary data acquisition systems, scope bays and other
destinations.
28608B cards are fitted with front panel connectors that
accept the output adapter modules. Adapters plug on to the front of the signal
conditioner card and are secured to the card by two screws. The adapters provide
two additional fully buffered outputs per channel on two high-density 26-pin D
shell connectors.
Download 28608B
Octal Programmable
Filter Amplifier Specification Sheet form the PF
Publications Library.
Back to top
Request
Product Information
|
-
Anti-Aliasing Filters with Programmable Amplifiers
-
Automatic Test Equipment
-
Data Acquisition
-
Signal Conditioning
-
Production Test Equipment
-
Industrial Process Control
-
Reconstruction Filters
-
Programmable Band-Pass Filters
Reference
The following Specifications
are available in Precision Filters'
On-line Library
for downloading:
28104A Quad Bridge Conditioner Specifications
28208 Octal Thermocouple Conditioner
28302B Dual
Vibration Amplifier
27304 Quad Dual Mode Charge Amplifier
28314 Quad Dynamic Charge/IEPE Conditioner
with LDTEDS
28316B 16-Channel TEDS/IEPE Accelerometer
Conditioner
28454A Quad Conditioner Specifications
28524 Quad Frequency to Voltage Converter
Modules
28608B Octal Programmable Filter Amplifier
27708A Octal
AC/DC Amplifier
|