PRECISION 28000
|
28208 Octal Thermocouple Conditioner
The 28208 Octal Thermocouple Conditioner provides eight channels of conditioning for thermocouples or other DC and AC voltage inputs. The 28208 consists of a low-drift programmable differential pre-amplifier, a 3-pole programmable filter and a programmable post-amplifier. A rugged remote isothermal block with digital temperature sensor provides the reference junction temperature for hardware correction. 28208 APPLICATIONS
Precision 28208 Features
28208 DescriptionThe 28208 channel consists of a low-drift programmable differential pre-amplifier, a 3-pole programmable filter and a programmable post-amplifier. Overall gain may be programmed to x1, 10, 100 or 1000. A programmable reserve setting of x1, 10 or 100 is provided for protection against out of band signals. For example, a reserve setting of 100 with a gain of 1000 will program the pre-amplifier to 10 and the post amplifier to 100, allowing the filter to reject out of band energy before all of the gain is applied. An open thermocouple condition or a channel overload condition is automatically detected and reported to the graphical user interface (GUI) software. Additionally, these fault conditions are indicated by 28208 front panel LEDs. A 3-pole programmable Bessel filter is provided with cutoff frequency settings of 1, 10 and 100. The filter may be bypassed to provide wide-band operation. A single-ended output stage is standard. The 28208 may be optionally fitted with a differential output. Isothermal BlockThe 28208-1-ITB Isothermal Block provides a reference junction for a single 28208 card (8-channels). Removable 3-pole terminal connectors allow for easy wiring of the thermocouples. The 28208-1-ITB has a 4-foot cable which mates directly with the 28208 input connector. Extension cables are available to locate the block remotely from the 28000 System. A removable cover provides a more stable environment while protecting the block.
For accurate cold junction compensation, the temperature of the isothermal block must be converted to the thermocouple thermoelectric voltage that would be generated if the junction were heated to the temperature that is measured. Thermocouple thermoelectric voltage has a non-linear relationship with temperature that is commonly referred to as "bowing". If a straight-line approximation to the thermoelectric voltage versus temperature were used, reference junction errors of over 1° C would result for a J-type thermocouple and over 2° for a T-type thermocouple. A digital temperature sensor on the 28208-1-ITB provides an accurate reading of the block temperature. The block temperature is interrogated once every 10 seconds. To remove errors caused by the bowing, a microcomputer in the 28208 sets a cold junction compensation DAC by calculating the correction voltage for the measured temperature based on NIST coefficients. Overall reference junction compensation accuracy is better than 0.6 degrees. 28208-2-ITB Isothermal Block Diagram |
Reference The following Specifications 28104A Quad Bridge Conditioner Specifications 28108 Octal Wideband Bridge Conditioner 28144 Quad-Channel Wideband Transducer Conditioner with Voltage and Current Excitation 28208 Octal Thermocouple Conditioner 28302B Dual 27304 Quad Dual Mode Charge Amplifier 28314 Quad Dynamic Charge/IEPE Conditioner with LDTEDS 28316C Isolated IEPE Accelerometer Conditioner with LDTEDS 28454A Quad Conditioner Specifications 28524 Quad Frequency to Voltage Converter Modules 28608B Octal Programmable Filter Amplifier 28708 Octal |
||
|
|